1.
Respir Res ; 25(1): 70, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38317182

RESUMO

BACKGROUND: Currently, there are no reliable clinical tools that allow non-invasive therapeutic support for patients with pulmonary arterial hypertension. This study aims to propose a low-frequency ultrasound device for pulmonary hypertension therapy and to demonstrate its potential. METHODS: A novel low-frequency ultrasound transducer has been developed. Due to its structural properties, it is excited by higher vibrational modes, which generate a signal capable of deeply penetrating biological tissues. A methodology for the artificial induction of pulmonary hypertension in sheep and for the assessment of lung physiological parameters such as blood oxygen concentration, pulse rate, and pulmonary blood pressure has been proposed. RESULTS: The results showed that exposure of the lungs to low-frequency ultrasound changed physiological parameters such as blood oxygen concentration, pulse rate and blood pressure. These parameters are most closely related to indicators of pulmonary hypertension (PH). The ultrasound exposure increased blood oxygen concentration over a 7-min period, while pulse rate and pulmonary blood pressure decreased over the same period. In anaesthetised sheep exposed to low-frequency ultrasound, a 10% increase in SpO2, a 10% decrease in pulse rate and an approximate 13% decrease in blood pressure were observed within 7 min. CONCLUSIONS: The research findings demonstrate the therapeutic efficiency of low-frequency ultrasound on hypertensive lungs, while also revealing insights into the physiological aspects of gas exchange within the pulmonary system.


Assuntos
Hipertensão Pulmonar , Humanos , Animais , Ovinos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/terapia , Pulmão/diagnóstico por imagem , Ultrassonografia , Pressão Sanguínea , Oxigênio
2.
Sensors (Basel) ; 23(7)2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-37050668

RESUMO

The safety of ultrasound exposure is very important for a patient's well-being. High-frequency (1-10 MHz) ultrasound waves are highly absorbed by biological tissue and have limited therapeutic effects on internal organs. This article presents the results of the development and application of a low-frequency (20-100 kHz) ultrasonic transducer for sonication of biological tissues. Using the methodology of digital twins, consisting of virtual and physical twins, an ultrasonic transducer has been developed that emits a focused ultrasound signal that penetrates into deeper biological tissues. For this purpose, the ring-shaped end surface of this transducer is excited not only by the main longitudinal vibrational mode, which is typical of the flat end surface transducers used to date, but also by higher mode radial vibrations. The virtual twin simulation shows that the acoustic signal emitted by the ring-shaped transducer, which is excited by a higher vibrational mode, is concentrated into a narrower and more precise acoustic wave that penetrates deeper into the biological tissue and affects only the part of the body to be treated, but not the whole body.


Assuntos
Sonicação , Ultrassom , Humanos , Desenho de Equipamento , Ultrassonografia , Transdutores